Comparison Study Of Minimally Invasive Plate Osteosynthesis (MIPO) Vs Open Reduction And Internal Fixation (ORIF) For Comminuted Distal Tibia Fracture

Authors

  • Mishkat Ullah Combined Military Hospital Rawalpindi, Pakistan
  • Suhail Amin Army Medical Collage Rawalpindi, Pakistan
  • Arsalan Raiz Combined Military Hospital Rawalpindi, Pakistan
  • Abid Rehaman Northwest General Hospital and Research Center Peshawar, Pakistan
  • Asnaf Siddique Type D Hospital Latambar Karak, Pakistan
  • . Khalid Combined Military Hospital Rawalpindi, Pakistan
  • Faisal Rafique Type D Hospital Latambar Karak, Pakistan

DOI:

https://doi.org/10.54112/bcsrj.v6i5.1723

Keywords:

Distal tibia fracture, MIPO, ORIF, fracture fixation, functional outcome, radiological union

Abstract

Comminuted distal tibia fractures are complex injuries that require precise management due to limited soft tissue coverage and high risk of complications. Two commonly used fixation techniques are minimally invasive plate osteosynthesis (MIPO) and open reduction and internal fixation (ORIF). Each method has distinct biomechanical and biological implications that influence healing outcomes. Objective: To compare the functional and radiological outcomes of MIPO versus ORIF in the treatment of comminuted distal tibia fractures. Methods: This prospective comparative study was conducted at the Department of Orthopedic Surgery, CMH Rawalpindi, from 15 June 2024 to 14 Feb 2025. A total of 60 patients were divided into two groups of 30 each, treated with either MIPO or ORIF. Functional outcomes were measured using the AOFAS score, and radiological union was assessed through serial X-rays. Results: The MIPO group showed significantly higher mean AOFAS scores (88.5 vs. 80.9), faster union times (15.2 vs. 17.6 weeks), and fewer complications compared to the ORIF group. Conclusion: MIPO is a superior technique for comminuted distal tibia fractures, offering better outcomes with fewer complications.

Downloads

Download data is not yet available.

References

- Sourougeon, Y., Barzilai, Y., Haba, Y., Spector, B. and Prat, D., 2023. Outcomes following Minimally Invasive Plate Osteosynthesis (MIPO) application in tibial pilon fractures–A systematic review. Foot and Ankle Surgery, 29(8), pp.566-575.

- Saini, D.R., Shah, D.N., Dholakia, D.A., Shah, D.D., Agrawal, D.K. and Patel, D.U., 2021. A prospective study on functional outcome of distal tibial fracture fixation with locking compression plate using minimally invasive percutaneous osteosynthesis technique. International Journal of Orthopaedics, 7(2), pp.20-4.

- Inam, M., Asadullah, M., Dawood, S. and Rahman, W.U., 2023. Minimal Invasive Plate Osteosynthesis for Distal Tibia Fractures.

- Mazyon, A.S., Jawad, M.J. and Hamadallah, O.A., 2023. Comparative Study Between Intramedullary Nail and Minimally Invasive Plate Osteosynthesis in Tibial Shaft Fracture. Azerbaijan Pharmaceutical and Pharmacotherapy Journal, 22, pp.183-186.

- Park, Y.U., Kim, S.J. and Kim, H.N., 2021. Minimally invasive plate osteosynthesis using the oblong hole of a locking plate for comminuted distal fibular fractures. Journal of Orthopaedic Surgery and Research, 16(1), p.281.

- Harshwardhan, H., Bhaskar, S.K., Raj, S., Patidar, R. and Nisar, A., 2024. FUNCTIONAL OUTCOME OF DISTAL TIBIA FRACTURES MANAGED BY MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS. Journal of Cardiovascular Disease Research, 15(11), pp.804-812.

- Singh, N., Paswan, A.K. and Jee, G.M., 2024. EVALUATION OF RESULTS OF MINIMALLY INVASIVE PLATING OSTEOSYNTHESIS (MIPO) TECHNIQUE IN THE TREATMENT OF FRACTURES OF DISTAL TIBIA. Int J Acad Med Pharm, 6(3), pp.851-854.

- Kc, K.M., Pangeni, B.R., Marahatta, S.B., Sigdel, A. and Kc, A., 2022. Comparative study between intramedullary interlocking nailing and minimally invasive percutaneous plate osteosynthesis for distal tibia extra-articular fractures. Chinese Journal of Traumatology, 25(2), pp.90-94.

- Agarwal, K. and Maniar, P., 2021. Study of results of extra articular distal tibial fracture treated with locking plate by minimally invasive percutaneous plate osteosynthesis. IJOS, 7(3), pp.720-6.

- Rusimov, L., Baltov, A., Enchev, D., Gueorguiev, B., Prodanova, K., Hadzhinikolova, M., Rusimov, V. and Rashkov, M., 2023. Comparison between open reduction and internal fixation and minimally invasive plate osteosynthesis for unstable proximal humerus fractures treated with locking plate and intramedullary allograft: a retrospective study.

- Makelov, B., 2023. MINIMALLY INVASIVE OSTEOSYNTHESIS WITH PLATE OR NAIL FOR META-DIAPHYSEAL TIBIAL FRACTURES-WHAT IS BETTER?. Trakia Journal of Sciences, 21(4), p.357.

- Abouelela, M.S., Hegazy, M.H., Emran, A.M. and El-Tabbakh, M.R., A Comparative Study between Results of Extraarticular Distal Tibia Fractures Fixed by Minimally Invasive Locked Plate versus Expert Nail. The Egyptian Journal of Hospital Medicine (January 2025), 98, pp.154-161.

- Verma, A.K., Agarwal, S., Garg, A.M., Prakash, S. and Choubisa, R., 2021. Evaluation of Radiological and Clinical Outcome of Minimally Invasive Plate Osteosynthesis (MIPO) for Metaphyseal Fracture of Distal Femur and Proximal Tibia. Journal of Bone and Joint Diseases, 36(3), pp.74-79.

- Paulsson, M., Ekholm, C., Tranberg, R., Rolfson, O. and Geijer, M., 2023. Using a traction table for fracture reduction during minimally invasive plate osteosynthesis (MIPO) of distal femoral fractures provides anatomical alignment. Journal of clinical medicine, 12(12), p.4044.

- Wu, H.J., He, Y.X., Hang, C., Hao, L. and Lin, T.K., 2022. AO distractor and manual traction reduction techniques repair in distal tibial fractures: a comparative study. BMC Musculoskeletal Disorders, 23(1), p.1081.

- Randhawa, P.S., Joshi, G. and Mankar, P.A., 2023. Outcomes of patients treated with minimally invasive plate osteosynthesis in the management of distal tibial fractures. International Journal of Research in Orthopaedics, 9(4), p.1.

.

Downloads

Published

2025-05-31

How to Cite

Ullah, M. ., Amin, S. ., Raiz, A. ., Rehaman, A. ., Siddique, A. ., Khalid, ., & Rafique, F. . (2025). Comparison Study Of Minimally Invasive Plate Osteosynthesis (MIPO) Vs Open Reduction And Internal Fixation (ORIF) For Comminuted Distal Tibia Fracture. Biological and Clinical Sciences Research Journal, 6(5), 7–11. https://doi.org/10.54112/bcsrj.v6i5.1723

Issue

Section

Original Research Articles

Most read articles by the same author(s)