Functional Outcomes of Distal Radius Fractures Undergoing Variable Angle Volar Locking Compression Plates
DOI:
https://doi.org/10.54112/bcsrj.v6i6.2128Keywords:
Distal radius fracture, Volar locking plate, Variable angle, Functional outcome, Mayo wrist score, Comorbidities.Abstract
Distal radius fractures are among the most common orthopedic injuries in adults, and stable fixation is essential to restore wrist function and prevent long-term disability. Variable-angle volar locking compression plates have gained popularity due to improved biomechanical stability and early mobilization. Objective: To determine the functional outcomes of distal radius fractures undergoing variable-angle volar locking compression plate management. Methods: Descriptive study. Study setting and duration: 10-11-2024 to10-05-2025 Department of Orthopaedic Surgery, Lady Reading Hospital, Peshawar. The present study was conducted on 75 patients aged 18-65 years with a distal radius fracture. Patients with open or complicated fractures were excluded. All patients underwent a variable-angle volar locking compression plate approach. The functional outcome was assessed 60 days after the procedure, using the modified Mayo wrist score. Data analysis was performed using SPSS 27, and frequency and percentages were used for functional outcomes. The chi-square test was used to evaluate the association between functional outcomes and demographics and comorbidities, with p-values < 0.05 considered significant. Results: Mean age of the cohort was 36.73 ± 11.93 years, with male gender 64.0% (n=48). The mean postoperative modified Mayo wrist score was 88.55 ± 5.82. Functional outcomes were excellent in 54.7% of cases (n=41) and good in 38.7% (n=29). Statistically significant association of fair functional outcome was found with increasing age, diabetes, hypertension, and smoking. Fewer complications were observed. Conclusion: Variable-angle volar locking compression plates for the management of distal radius fractures demonstrated excellent to good outcomes in the majority of patients. The procedure showed a favorable safety profile with minimal complications.
Downloads
References
Del Piñal F, Jupiter JB, Rozental TD, Arora R, Nakamura T, Bain GI. Distal radius fractures. J Hand Surg. 2022;47(1):12–23. https://doi.org/10.1177/17531934211028711
Tsai YY, Shen HC. High-energy trauma leading to Galeazzi injury and distal radius fracture. CMAJ. 2025;197(34):E1113. https://doi.org/10.1503/cmaj.250385
Garg DK, Sakale H, Agrawal AC, Kar B, Pandiyarajan E, Yadav SK. Evaluation of the functional and radiological outcomes of fixed-angle versus variable-angle volar locking compression plates in managing intra-articular fractures of the distal end of the radius. Malays Orthop J. 2025;19(2):9–17. https://doi.org/10.5704/MOJ.2507.002
Abdel-Wahed M, Khater AA, El-Desouky MA. Volar locking plate fixation for distal radius fractures: did variable-angle plates make difference? Int Orthop. 2022;46(9):2165–2176. https://doi.org/10.1007/s00264-022-05469-z
Emet A, Veizi E, Karaman Y, Akgun E, Tolunay T, Firat A. Volar fixed plating of distal radius fractures: optimizing plate position for enhanced clinical outcomes. BMC Musculoskelet Disord. 2024;25(1):320. https://doi.org/10.1186/s12891-024-07415-z
Hassan HU, Tariq M, Anwar BA. Functional outcomes of distal radius fractures managed with 2.7 mm variable angle volar locking compression plates. Pak Postgrad Med J. 2022;33(3):68–71
Khan AM, Ali B, Yusuf M, Khursheed B, Farooq OM, Muhammad N. K-wiring versus plating: a comparative study on the outcomes in distal radius fractures. Pak J Med Health Sci. 2023;17(9):253–256. https://doi.org/10.53350/pjmhs20231709253
Rehman S, Hussain B, Ullah N, Gul Y. Comparison between percutaneous fixation using Kirschner wires with volar locking plate fixation in adults with dorsally displaced fracture of distal radius. Pak J Med Res. 2024;63(3):121–124.
Kumar KP, Hawaldar SV, Patil M. Functional outcome of volar variable angle locking compression plate in distal end radius fractures: a retrospective case record analysis. J Orthop Dis Traumatol. 2023;6(1):84–89. https://doi.org/10.4103/jodp.jodp_72_22
Singh PB, Pradeep E, Janeson JD, Kumar KA, Sheik M, Gopi P. Clinicoradiological outcome of variable angle volar locking plate in the management of distal radius fractures. J Orthop Case Rep. 2025;15(4):270–276. https://doi.org/10.13107/jocr.2025.v15.i04.5518
Ajith K, Panackathottam M, Subbaiah GP, Jishnu VN. Functional and radiological outcome measures of surgically treated unstable distal radius fractures using a variable angle volar locking compression plate. Int J Health Sci. 2022;6(S5):9189–9199. https://doi.org/10.53730/ijhs.v6nS5.10696
Lal JV, Krishnan R, George AJ, Krishnamurthy SL, Pilar A, Amaravathi RS. Functional outcome of intra-articular distal radius fractures treated with volar variable angled locking compression plate at a tertiary care center. J Orthop Assoc South Indian States. 2023;20(2):75–80. https://doi.org/10.4103/joasis.joasis_19_23
Kumar S, Kumar H, Gupta PK, Rajendra K, Baijal A, Yadav S, et al. Functional outcomes of intra-articular distal radius fractures: single-incision three-column fixation using volar locking plate and K-wire stabilization. Cureus. 2025;17(9):e92032. https://doi.org/10.7759/cureus.92032
Patel S, Deshmukh A, Yadav P, Phalak M, Gumani S, Yadav S, et al. Assessment of functional and radiological outcomes of comminuted intra-articular distal radius fracture treated with locking compression plate. Cureus. 2022;14(1):e21398. https://doi.org/10.7759/cureus.21398
Ullah H, Hassan HU, Tariq M, Anwar BA. Functional outcomes of distal radius fractures managed with 2.7 mm variable angle volar locking compression plates. Pak Postgrad Med J. 2022;33(3):68–71. https://doi.org/10.51642/ppmj.v33i03.485
Fowler JR, Ilyas AM. Prospective evaluation of distal radius fractures treated with variable-angle volar locking plates. J Hand Surg Am. 2013;38(11):2198–2203. https://doi.org/10.1016/j.jhsa.2013.08.116
Iqbal MF, Javed S, Ageel Z, Saleem MU, Iqbal U, Iqbal MS. Good to excellent functional outcome of volar locking plate fixation distal radius fracture. Indus J Biosci Res. 2025;3(7):1142–1146. https://doi.org/10.70749/ijbr.v3i7.2427
Nandan A, Shekhar R, Kumar R. Functional outcomes of volar locking plate fixation in distal radius fractures: a prospective study. Int J Curr Pharm Rev Res. 2024;16(11):324–328.
Hart A, Collins M, Chhatwal D, Steffen T, Harvey EJ, Martineau PA. Can the use of variable-angle volar locking plates compensate for suboptimal plate positioning in unstable distal radius fractures? A biomechanical study. J Orthop Trauma. 2015;29(1):e1–e6. https://doi.org/10.1097/BOT.0000000000000146
Kotian P, Mudiganty S, Annappa R, Austine J. Radiological outcomes of distal radius fractures managed with 2.7 mm volar locking plate fixation: a retrospective analysis. J Clin Diagn Res. 2017;11(1):RC09–RC12. https://doi.org/10.7860/JCDR/2017/24773.9282
Nishiwaki M, Terasaka Y, Kiyota Y, Inaba N, Koyanagi T, Horiuchi Y. A prospective randomized comparison of variable-angle and fixed-angle volar locking plating for intra-articular distal radius fractures. J Hand Surg Am. 2021;46(7):584–593. https://doi.org/10.1016/j.jhsa.2021.03.014
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Danish Khan, Baqir Hussain

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.


