DIAGNOSTIC ACCURACY OF ALLENS TEST FOR ULNAR COLLATERAL FLOW IN RADIAL ARTERY HARVESTING IN CORONARY ARTERY BYPASS GRATING

Authors

  • M AAMIR Department of cardiac surgery, Jinnah Hospital, Lahore-Pakistan
  • T INAM Department of Anatomy, kind Edward Medical University (KEMU) Lahore- Pakistan
  • H IQBAL Department of cardiac surgery, Rehmatul Lil Alameen Institute of Cardiology (RAIC), Lahore- Pakistan
  • W KHALID Department of cardiac surgery, Rehmatul Lil Alameen Institute of Cardiology (RAIC), Lahore- Pakistan

DOI:

https://doi.org/10.54112/bcsrj.v2022i1.166

Keywords:

Doppler Ultrasonography, Allen's Test, Diagnostic accuracy, Radial artery, gold standard

Abstract

To treat coronary artery disease, coronary artery bypass graft (CABG) surgery is done worldwide (CAD). Before harvesting the radial artery for cardiac bypass surgery, Allen's test is frequently used to evaluate the hand's ulnar collateral blood supply. Using Doppler Ultrasonography as a gold standard, this study was created to evaluate the diagnostic precision of Allen's test for the ulnar collateral flow of the donor limb before radial artery
harvesting. This cross-sectional study was conducted from January 2015 to September 2017 at the Jinnah Hospital in Lahore's Cardiac Surgery department. The consecutive sampling/non-probability method was employed. A signed consent form was obtained, and specific demographic data (name, age, and gender) was gathered. SPSS version 21 was used to enter and analyze all of the data. The patients in our study had a mean age of 50.91±9.13 years. The ratio of men to women was 1.3:1. The sensitivity, specificity, PPV, NPV and diagnostic accuracy of Allen’s test was 77.05%, 81.36%, 81.03%, 77.42% & 79.17% taking Doppler test as gold standard. Allen's test, which uses Doppler ultrasonography as the gold standard, is a reliable and valid screening test for the ulnar collateral flow of the donor limb before radial artery harvesting, according to the findings of our study.

Downloads

Download data is not yet available.

References

Abu-Omar, Y., Mussa, S., Anastasiadis, K., Steel, S., Hands, L., and Taggart, D. P. (2004). Duplex ultrasonography predicts safety of radial artery harvest in the presence of an abnormal Allen test. The Annals of thoracic surgery 77, 116-119.

Agrifoglio, M., Dainese, L., Pasotti, S., Galanti, A., Cannata, A., Roberto, M., Parolari, A., and Biglioli, P. (2005). Preoperative assessment of the radial artery for coronary artery bypass grafting: is the clinical Allen test adequate? The Annals of thoracic surgery 79, 570-572.

Al-metwalli, R. R. (2019). Perfusion index as an objective alternative to the Allen test, with flow quantification and medico legal documentation. Anaesthesia, Pain & Intensive Care, 245-249.

Al-Sabti, H. A., Al Kindi, A., Al-Rasadi, K., Banerjee, Y., Al-Hashmi, K., and Al-Hinai, A. (2013). Saphenous vein graft vs. radial artery graft searching for the best second coronary artery bypass graft. Journal of the Saudi Heart Association 25, 247-254.

Athanasiou, T., Saso, S., Rao, C., Vecht, J., Grapsa, J., Dunning, J., Lemma, M., and Casula, R. (2011). Radial artery versus saphenous vein conduits for coronary artery bypass surgery: forty years of competition—which conduit offers better patency? A systematic review and meta-analysis. European Journal of Cardio-Thoracic Surgery 40, 208-220.

Baetz, L., and Satiani, B. (2011). Palmar arch identification during evaluation for radial artery harvest. Vascular and endovascular surgery 45, 255-257.

Barbeau, G. R., Arsenault, F., Dugas, L., Simard, S., and Larivière, M. M. (2004). Evaluation of the ulnopalmar arterial arches with pulse oximetry and plethysmography: comparison with the Allen's test in 1010 patients. American heart journal 147, 489-493.

Cable, D. G., Mullany, C. J., and Schaff, H. V. (1999). The Allen test. The Annals of thoracic surgery 67, 876-877.

Carpentier, A., Guermonprez, J., Deloche, A., Frechette, C., and DuBost, C. (1973). The aorta-to-coronary radial artery bypass graft: a technique avoiding pathological changes in grafts. The Annals of Thoracic Surgery 16, 111-121.

Chen, X., Chen, X., Xie, D., Meng, F., Shi, K., and Xu, M. (2009). Radial artery as conduit is safe and effective in coronary bypass surgery in the elderly single-central results from 326 patients. Circulation Journal 73, 1049-1054.

Fox, A. D., Whiteley, M. S., Phillips-Hughes, J., and Roake, J. (1999). Acute upper limb ischemia: a complication of coronary artery bypass grafting. The Annals of thoracic surgery 67, 535-536.

Geha, A. S., Krone, R. J., McCormick, J. R., and Baue, A. E. (1975). Selection of coronary bypass: anatomic, physiological, and angiographic considerations of vein and mammary artery grafts. The Journal of Thoracic and Cardiovascular Surgery 70, 414-431.

Habib, J., Baetz, L., and Satiani, B. (2012). Assessment of collateral circulation to the hand prior to radial artery harvest. Vascular Medicine 17, 352-361.

Jarvis, M. A., Jarvis, C. L., Jones, P. R., and Spyt, T. J. (2000). Reliability of Allen's test in selection of patients for radial artery harvest. The Annals of thoracic surgery 70, 1362-1365.

Kohonen, M., Teerenhovi, O., Terho, T., Laurikka, J., and Tarkka, M. (2007). Is the Allen test reliable enough? European journal of cardio-thoracic surgery 32, 902-905.

Manabe, S., Tabuchi, N., Toyama, M., Kuriu, K., Mizuno, T., and Sunamori, M. (2002). Measurement of ulnar flow is helpful in predicting ischemia after radial artery harvest. The Thoracic and Cardiovascular Surgeon 50, 325-328.

Mussa, S., Choudhary, B. P., and Taggart, D. P. (2005). Radial artery conduits for coronary artery bypass grafting: current perspective. The Journal of thoracic and cardiovascular surgery 129, 250-253.

Rani, C. R., Rao, B. N., and Padmini, M. P. (2012). UNILATERAL INCOMPLETE SUPERFICIAL PALMAR ARCH-A CASE REPORT. International Journal of Current Research and Review 4, 125.

Ronald, A., Patel, A., and Dunning, J. (2005). Is the Allen's test adequate to safely confirm that a radial artery may be harvested for coronary arterial bypass grafting? Interactive CardioVascular and Thoracic Surgery 4, 332-340.

Schena, S., Crabtree, T. D., Baker, K. A., Guthrie, T. J., Curci, J., Damiano, R. J., and Barner, H. B. (2011). Absence of deterioration of vascular function of the donor limb at late follow-up after radial artery harvesting. The Journal of Thoracic and Cardiovascular Surgery 142, 298-301.

Starnes, S. L., Wolk, S. W., Lampman, R. M., Shanley, C. J., Prager, R. L., Kong, B. K., Fowler, J. J., Page, J. M., Babcock, S. L., and Lange, L. A. (1999). Noninvasive evaluation of hand circulation before radial artery harvest for coronary artery bypass grafting. The Journal of Thoracic and Cardiovascular Surgery 117, 261-266.

Tatoulis, J., Royse, A. G., Buxton, B. F., Fuller, J. A., Skillington, P. D., Goldblatt, J. C., Brown, R. P., and Rowland, M. A. (2002). The radial artery in coronary surgery: a 5-year experience—clinical and angiographic results. The Annals of thoracic surgery 73, 143-148.

Weiss, A. J., Zhao, S., Tian, D. H., Taggart, D. P., and Yan, T. D. (2013). A meta-analysis comparing bilateral internal mammary artery with left internal mammary artery for coronary artery bypass grafting. Annals of cardiothoracic surgery 2, 390.

Wood, J. W., Broussard, K. C., and Burkey, B. (2013). Preoperative testing for radial forearm free flaps to reduce donor site morbidity. JAMA Otolaryngology–Head & Neck Surgery 139, 183-186.

Downloads

Published

2023-01-03

How to Cite

AAMIR, M., INAM, T., IQBAL, H., & KHALID, W. (2023). DIAGNOSTIC ACCURACY OF ALLENS TEST FOR ULNAR COLLATERAL FLOW IN RADIAL ARTERY HARVESTING IN CORONARY ARTERY BYPASS GRATING. Biological and Clinical Sciences Research Journal, 2022(1). https://doi.org/10.54112/bcsrj.v2022i1.166

Issue

Section