ACCURACY OF SHEAR WAVE ELASTOGRAPHY IN THE DIAGNOSIS OF HEPATIC FOCAL LESIONS

Authors

  • MA SHAHZAD Department of Radiology, Nishtar Medical University & Hospital Multan, Pakistan
  • S MUSHTAQ Department of Radiology, Nishtar Medical University & Hospital Multan, Pakistan
  • H MASOOD Department of Radiologist, Zeenat Hospital Multan, Pakistan
  • D MASOOD Shifa College of Medicine, Islamabad, Pakistan
  • R AHMED Department of Biochemistry, Independent Medical College Faisalabad, Pakistan

DOI:

https://doi.org/10.54112/bcsrj.v2023i1.625

Keywords:

Shear Wave Elastography, CT Scan, Hepatic Malignancy, Ultrasound

Abstract

This study aimed to evaluate the accuracy of Shear Wave Elastography (SWE) in diagnosing hepatic focal lesions using triphasic CT as the gold standard. The study was conducted prospectively at the Department of Radiology, Nishtar Medical Hospital, from January 2022 to January 2023. Patients with at least one hepatic focal lesion ranging from 1 to 5 cm in diameter were included in the study. All patients underwent SWE scanning and ultrasound examination. The segment of focal lesions was evaluated, and 5-8 measurements were taken for quantitative analysis of stiffness. In patients with multiple focal lesions, the pathology of all lesions was confirmed by MRI and CT, and the most accessible lesion was analyzed. The mean of all measurements was compared with the findings of triphasic CT and tumor markers to estimate SWE's accuracy, specificity, and sensitivity. The study was conducted on 100 patients, of which 85 were males and 17 were females. The mean stiffness in benign lesions was 10.4 ± 6.32 kPa, and in malignant lesions was 16.3 ± 9.24 kPa. This difference was statistically significant (P<.002). A cutoff value 13.25 was used to differentiate between malignant and benign lesions. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of SWE were 78.05%, 71.43%, 88.9%, 52.3%, and 64.3%, respectively. The mean tissue stiffness in focal fatty infiltration was 12.7 ± 8.9 kPa, and in hemangioma lesions was 9.6 ± 4.3 kPa. The mean stiffness in HCC was 15.5 ± 7.1 kPa, in cholangiocarcinoma was 32.6 ± 8.26 kPa, and in metastatic lesions was 22.2 ± 0.5 kPa. In conclusion, SWE has a high sensitivity, specificity, and accuracy for differentiating malignant and benign hepatic focal lesions. The study shows that the stiffness of benign and malignant lesions differs significantly.

Downloads

Download data is not yet available.

References

Alem, S. A., Omar, H., Zayed, N., Mabrouk, M., and Yosry, A. (2023). Clinical value of acoustic radiation force impulse elastography in predicting hepatocellular carcinoma in chronic hepatitis C patients. Egyptian Liver Journal 13, 22.

Chimoriya, R., Piya, M. K., Simmons, D., Ahlenstiel, G., and Ho, V. (2020). The use of two-dimensional shear wave elastography in people with obesity for the assessment of iver fibrosis in non-alcoholic fatty liver disease. Journal of Clinical Medicine 10, 95.

Constantinescu, C., and Saftoiu, A. (2019). A brief report on EFSUMB Guidelines and Recommendations for elastography and contrast-enhanced ultrasound. Medical Ultrasonography 21, 5-7.

Corvino, A., Sandomenico, F., Setola, S. V., Corvino, F., Tafuri, D., and Catalano, O. (2019). Morphological and dynamic evaluation of complex cystic focal liver lesions by contrast-enhanced ultrasound: current state of the art. Journal of Ultrasound 22, 251-259.

Dong, Y., Koch, J., Alhyari, A., Zadeh, E. S., Görg, C., Wang, W.-P., Berzigotti, A., and Dietrich, C. F. (2023). Ultrasound Elastography for Characterization of Focal Liver Lesions. Zeitschrift für Gastroenterologie 61, 399-410.

Dong, Y., Qiu, Y., Zhang, Q., Yang, D., Yu, L., Wang, W.-P., and Dietrich, C. F. (2020). Preliminary clinical experience with shear wave dispersion imaging for liver viscosity in preoperative diagnosis of focal liver lesions. Zeitschrift für Gastroenterologie 58, 847-854.

Ferraioli, G., Tinelli, C., Dal Bello, B., Zicchetti, M., Filice, G., Filice, C., and Group, L. F. S. (2012). Accuracy of real‐time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study. Hepatology 56, 2125-2133.

Herrmann, E., de Lédinghen, V., Cassinotto, C., Chu, W. C. W., Leung, V. Y. F., Ferraioli, G., Filice, C., Castera, L., Vilgrain, V., and Ronot, M. (2018). Assessment of biopsy‐proven liver fibrosis by two‐dimensional shear wave elastography: An individual patient data‐based meta‐analysis. Hepatology 67, 260-272.

Jesper, D., Fiedler, S., Klett, D., Waldner, M. J., Schellhaas, B., Zundler, S., Neurath, M. F., and Pfeifer, L. (2022). Shear Wave Dispersion Imaging for the Characterization of Focal Liver Lesions–A Pilot study. Ultraschall in der Medizin-European Journal of Ultrasound 43, 507-513.

KOTNIS, S., NAGARAJ, R. H., and RAJANNA BRAHMA, P. J. (2021). Role of MRI in Evaluation of Focal Liver Lesions: A Cross-sectional Study. Journal of Clinical & Diagnostic Research 15.

Moustafa, E. F., Makhlouf, N., Hassany, S. M., Helmy, A., Nasr, A., Othman, M., Seif, H., Darwish, M., Hassan, H., and Hessen, M. (2017). Non-invasive assessment of liver fibrosis in patients with hepatitis C: Shear wave elastography and colour Doppler velocity profile technique versus liver biopsy. Arab journal of gastroenterology 18, 6-12.

Nagarajan, K. (2019). Efficacy of Ultrasound Elastography in Characterizing Focal Liver Lesions with Histopathologic Correlation, Madras Medical College, Chennai.

Nakayama, R., Takaya, Y., Nakamura, K., Kondo, M., Kobayashi, K., Ohno, Y., Amioka, N., Akagi, S., Yoshida, M., and Miyoshi, T. (2021). Efficacy of shear wave elastography for evaluating right ventricular myocardial fibrosis in monocrotaline-induced pulmonary hypertension rats. Journal of cardiology 78, 17-23.

RANIA, R., AWADALLAH, M., MAHMOUD, Y. L., and REDA, S. (2022). Can Shearwave Elastography as an Adjunct Non-Invasive Technique to Ultrasound Help in Better Characterization of Focal Liver Lesions? The Medical Journal of Cairo University 90, 2253-2262.

Ruan, S.-m., Huang, H., Cheng, M.-q., Lin, M.-x., Hu, H.-t., Huang, Y., Li, M.-d., Lu, M.-d., and Wang, W. (2023). Shear-wave elastography combined with contrast-enhanced ultrasound algorithm for noninvasive characterization of focal liver lesions. La radiologia medica 128, 6-15.

Downloads

Published

2023-12-28

How to Cite

SHAHZAD , M., MUSHTAQ , S., MASOOD , H., MASOOD , D., & AHMED , R. (2023). ACCURACY OF SHEAR WAVE ELASTOGRAPHY IN THE DIAGNOSIS OF HEPATIC FOCAL LESIONS. Biological and Clinical Sciences Research Journal, 2023(1), 625. https://doi.org/10.54112/bcsrj.v2023i1.625

Most read articles by the same author(s)

1 2 > >>