MYOCARDIAL FLOW RESERVE MEASUREMENT USING CADMIUM ZINC-TELLURIDE SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY MYOCARDIAL PERFUSION IMAGING AND RELATION TO ANGIOGRAPHIC CORONARY ARTERY DISEASE

Authors

  • S ASLAM Armed Forces Institute of Cardiology & National Institute of Heart Diseases, Rawalpindi, Pakistan
  • U ASLAM Armed Forces Institute of Cardiology & National Institute of Heart Diseases, Rawalpindi, Pakistan
  • K AHMED Children Hospital Lahore, Pakistan
  • S ASLAM Azad Jammu Kashmir Medical College, AJK, Pakistan
  • M KALEEM Azad Jammu Kashmir Medical College, AJK, Pakistan
  • S ASLAM Combined Milltary Hospital abbottabad, Pakistan

DOI:

https://doi.org/10.54112/bcsrj.v2024i1.1426

Keywords:

Coronary artery disease, Cadmium Zinc-Telluride, SPECT MPI, Myocardial blood flow, Myocardial flow reserve

Abstract

The addition of Myocardial flow reserve (MFR) to Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging (MPI) by using Cadmium Zinc Telluride (CZT) camera for screening of CAD may improve high-risk patient identification and diagnostic performance. Objective: This study aimed to assess the severity of coronary artery disease using MFR by SPECT MPI and comparing it with angiography finding. Methods: It was a cross-sectional study which was carried out in Armed Forces institute of cardiology and National Institute of Heart Diseases, Rawalpindi from June to Oct 2024. The myocardial flow reserve was calculated using Cadmium Zinc Telluride with 99mTc-sestamibi as radiotracer using SPECT MPI. Disease severity was also assessed using coronary angiography. Chi-square and Fischer exact test was applied for cross-tabulation. Kappa statistics was used to determine the level of agreement between the procedures. P-value less than 0.05 was taken as statistically significant. Results: The 100 patients with mean age of 64.90 + 3.60 years. The mean myocardial blood flow at rest is 1.06 + 0.18 mL/g/min, and at stress is 2.42 + 0.74 mL/g/min. The Myocardial flow reserve mean was 2.23 + 0.52 mL/g/min across sample of study. There is no association between CAD severity determined by SPECT MPI and demographic factors (p > 0.05). Coronary artery disease severity determined by Myocardial flow reserve (MFR) using SPECT MPI and angiography showed statistical significance with p-value of <0.001 and strong agreement with kappa value of 0.784, suggesting MPI SPECT a valuable tool for determining coronary artery disease severity. Conclusion: Cadmium Zinc Telluride gamma camera in SPECT MPI is a user-friendly, non-invasive and low-dose dynamic modality which provides a role of effective indicator of CAD. Myocardial reserve flow played significant role in determination of coronary artery disease severity, suggesting lower the mean myocardial reserve flow the higher the severity of the coronary artery disease. The association between them is also independent of the patient demographics, traditional risk factors and cardiovascular health of the patients, which make SPECT MPI as an independent alternative viable option for diagnosis of CAD.

Downloads

Download data is not yet available.

References

Vliegenthart R. Future Trends in CT for Coronary Artery Disease: From Diagnosis to Prevention. Radiology. 2023 May;307(3):e223285. doi: 10.1148/radiol.223285.

Zilla P, Bolman RM 3rd, Boateng P, Sliwa K. A glimpse of hope: cardiac surgery in low- and middle-income countries (LMICs). Cardiovasc Diagn Ther. 2020 Apr;10(2):336-349. doi: 10.21037/cdt.2019.11.03.

Shao C, Wang J, Tian J, Tang YD. Coronary Artery Disease: From Mechanism to Clinical Practice. Adv Exp Med Biol. 2020;1177:1-36. doi: 10.1007/978-981-15-2517-9_1.

Alam L, Omar AMS, Patel KK. Improved Performance of PET Myocardial Perfusion Imaging Compared to SPECT in the Evaluation of Suspected CAD. Curr Cardiol Rep. 2023 Apr;25(4):281-293. doi: 10.1007/s11886-023-01851-4.

D'Antonio A, Assante R, Zampella E, Mannarino T, Buongiorno P, Cuocolo A et al. Myocardial blood flow evaluation with dynamic cadmium-zinc-telluride single-photon emission computed tomography: Bright and dark sides. Diagn Interv Imaging. 2023 Jul-Aug;104(7-8):323-329. doi: 10.1016/j.diii.2023.02.001.

Pang ZK, Wang J, Chen Y, Chu HX, Zhang MY, Li JM. [Diagnostic efficiency and incremental value of myocardial blood flow quantification by CZT SPECT for patients with coronary artery disease]. Zhonghua Xin Xue Guan Bing Za Zhi. 2022 May 24;50(5):494-500. Chinese. doi: 10.3760/cma.j.cn112148-20211124-01018.

Aljizeeri A, Ahmed AI, Alfaris MA, Ahmed D, Farea J, Elneama A et al. Myocardial Flow Reserve and Coronary Calcification in Prognosis of Patients With Suspected Coronary Artery Disease. JACC Cardiovasc Imaging. 2021 Dec;14(12):2443-2452. doi: 10.1016/j.jcmg.2021.01.024.

Dahdal J, Jukema RA, Harms HJ, Cramer MJ, Raijmakers PG, Knaapen P et al. PET myocardial perfusion imaging: Trends, challenges, and opportunities. J Nucl Cardiol. 2024 Oct;40:102011. doi: 10.1016/j.nuclcard.2024.102011.

Miller RJH, Manabe O, Tamarappoo B, Hayes S, Friedman JD, Slomka PJ et al. Comparative Prognostic and Diagnostic Value of Myocardial Blood Flow and Myocardial Flow Reserve After Cardiac Transplantation. J Nucl Med. 2020 Feb;61(2):249-255. doi: 10.2967/jnumed.119.229625.

Mohammed AQ, Abdu FA, Liu L, Yin G, Mareai RM, Mohammed AA et al. Coronary microvascular dysfunction and myocardial infarction with non-obstructive coronary arteries: Where do we stand? Eur J Intern Med. 2023 Nov;117:8-20. doi: 10.1016/j.ejim.2023.07.016.

Thakur U, Nogic J, Comella A, Nerlekar N, Chan J, Abrahams T, et al. Computed tomography coronary angiography assessment of left main coronary artery stenosis severity. J Cardiovasc Comput Tomogr. 2024 Jul 17:S1934-5925(24)00393-9. doi: 10.1016/j.jcct.2024.07.005.

Zampella E, Assante R, Gaudieri V, Nappi C, Acampa W, Cuocolo A. Myocardial perfusion reserve by using CZT: It's a long way to the top if you wanna standardize. J Nucl Cardiol. 2021 Jun;28(3):885-887. doi: 10.1007/s12350-019-01817-6.

Zhang J, Xie J, Li M, Fang W, Hsu B. SPECT myocardial blood flow quantitation for the detection of angiographic stenoses with cardiac-dedicated CZT SPECT. J Nucl Cardiol. 2023 Dec;30(6):2618-2632. doi: 10.1007/s12350-023-03334-z.

de Souza ACDAH, Gonçalves BKD, Tedeschi AL, Lima RSL. Quantification of myocardial flow reserve using a gamma camera with solid-state cadmium-zinc-telluride detectors: Relation to angiographic coronary artery disease. J Nucl Cardiol. 2021 Jun;28(3):876-884. doi: 10.1007/s12350-019-01775-z.

Di Carli M, Czernin J, Hoh CK, Gerbaudo VH, Brunken RC, Huang SC et al. Relation among stenosis severity, myocardial blood flow, and flow reserve in patients with coronary artery disease. Circulation. 1995 Apr 1;91(7):1944-51. doi: 10.1161/01.cir.91.7.1944.

Joutsiniemi E, Saraste A, Pietilä M, Mäki M, Kajander S, Ukkonen H, Airaksinen J, Knuuti J. Absolute flow or myocardial flow reserve for the detection of significant coronary artery disease?. Eur Heart J Cardiovasc Imaging. 2014 Jun;15(6):659-65. doi: 10.1093/ehjci/jet274.

Ding A, Qiu G, Lin W, Hu L, Lu G, Long X, Hong X, Chen Y, Luo X, Tang Q, Deng D. Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in ischemia-causing coronary stenosis: a meta-analysis. Jpn J Radiol. 2016 Dec;34(12):795-808. doi: 10.1007/s11604-016-0589-4.

Wang S, Kim P, Wang H, Ng MY, Arai AE, Singh A, et al. Myocardial Blood Flow Quantification Using Stress Cardiac Magnetic Resonance Improves Detection of Coronary Artery Disease. JACC Cardiovasc Imaging. 2024 Sep 6:S1936-878X(24)00313-9. doi: 10.1016/j.jcmg.2024.07.023.

Gregg S, Keramida G, Peters AM. Measuring myocardial blood flow with 82rubidium using Gjedde-Patlak-Rutland graphical analysis. Ann Nucl Med. 2021 Jul;35(7):777-784. doi: 10.1007/s12149-021-01591-x.

Alahdab F, Ahmed AI, Nayfeh M, Han Y, Abdelkarim O, Alfawara MS et al. Myocardial Blood Flow Reserve, Microvascular Coronary Health, and Myocardial Remodeling in Patients With Aortic Stenosis. J Am Heart Assoc. 2024 Jun 4;13(11):e033447. doi: 10.1161/JAHA.123.033447.

Maltseva A, Kop’eva K, Mochula A, Gulya M, Dymbrylova O, Grakova E, et al. Association of impaired myocardial flow reserve with risk factors for cardiovascular diseases in patients with nonobstructive coronary artery disease. Russian Journal of Cardiology. 2023;28(2):5158. https://doi.org/10.15829/1560-4071-2023-5158.

Ko KY, Ko CL, Lee CM, Cheng JS, Wu YW, Hsu RB et al. Myocardial Flow Assessment After Heart Transplantation Using Dynamic Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography With 201Tl and 99mTc Tracers and Validated by 13N-NH3 Positron Emission Tomography. Circ Cardiovasc Imaging. 2023 Jun;16(6):e015034. doi: 10.1161/CIRCIMAGING.122.015034.

Yamamoto A, Nagao M, Ando K, Nakao R, Matsuo Y, Sakai A et al. First Validation of Myocardial Flow Reserve Derived from Dynamic 99mTc-Sestamibi CZT-SPECT Camera Compared with 13N-Ammonia PET. Int Heart J. 2022;63(2):202-209. doi: 10.1536/ihj.21-487.

Agostini D, Roule V, Nganoa C, Roth N, Baavour R, Parienti JJ et al. First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study. Eur J Nucl Med Mol Imaging. 2018 Jul;45(7):1079-1090. doi: 10.1007/s00259-018-3958-7.

Tsao NL, Abramowitz S, Shakt G, Judy R, Damrauer SM, Levin M. Angiographic Burden Of Coronary Atherosclerosis Contributes To Adverse ASCVD Outcomes Independent Of Traditional Risk Factors. Arteriosclerosis, Thrombosis, and Vascular Biology. 2024;44(Suppl_1):A3119-A.

Mangalesh S, Yadav P, Dudani S, Mahesh NK. Atherogenic index of plasma predicts coronary artery disease severity and major adverse cardiac events in absence of conventional risk factors. Coron Artery Dis. 2022 Nov 1;33(7):523-530. doi: 10.1097/MCA.0000000000001166.

Gobbo MY, Meretta AH, Sciancalepore M, Retamozo E, Beber E, Rosa D, et al. INOCA: Evaluación no invasiva de los mecanismos fisiopatológicos mediante CZT-SPECT. Revista argentina de cardiología. 2022;90(3):194-202. https://doi.org/10.7775/rac.es.v90.i3.20515.

Bereta M, Babečka J, Straka J, Valko P, Lacko A, editors. The Benefits of Nuclear Cardiology Examinations Using Cardiologic SPECT Gamma Camera. 2023 14th International Conference on Measurement; 2023: IEEE. 10.23919/measurement59122.2023.10164545.

Downloads

Published

2024-12-30

How to Cite

ASLAM, S., ASLAM, U., AHMED, K., ASLAM, S., KALEEM, M., & ASLAM, S. (2024). MYOCARDIAL FLOW RESERVE MEASUREMENT USING CADMIUM ZINC-TELLURIDE SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY MYOCARDIAL PERFUSION IMAGING AND RELATION TO ANGIOGRAPHIC CORONARY ARTERY DISEASE. Biological and Clinical Sciences Research Journal, 2024(1), 1426. https://doi.org/10.54112/bcsrj.v2024i1.1426

Most read articles by the same author(s)

1 2 > >>