FUNCTIONAL OUTCOMES OF PROXIMAL HUMERUS FRACTURE USING PHILOS

Authors

  • SU HAQ Department of Orthopedic, Hayatabad Medical Complex Peshawar, Pakistan
  • M SAEED Department of Orthopedic, Hayatabad Medical Complex Peshawar, Pakistan
  • M QASIM Department of Orthopedic, Hayatabad Medical Complex Peshawar, Pakistan
  • M HUSSAIN Department of Orthopedic, Hayatabad Medical Complex Peshawar, Pakistan

DOI:

https://doi.org/10.54112/bcsrj.v2024i1.1285

Keywords:

Proximal Humeral Fractures, PHILOS Plate, Functional Outcome, Complications, Constant-Murley Score, DASH Score

Abstract

Proximal humeral fractures are among the most common upper extremity fractures, particularly in adults, and their management remains a challenge. The Proximal Humerus Internal Locking System (PHILOS) plate fixation is widely used for these fractures, offering stability and enabling early mobilization. However, functional outcomes and potential complications require thorough evaluation to ensure optimal patient care. Objective: To assess the functional outcomes of Proximal Humerus Internal Locking System (PHILOS) plate fixation in patients with proximal humeral fractures. Methods: This prospective observational study was carried out at the orthopaedic department from July 2023 to July 2024. Participants included patients aged 20 years and older with proximal humeral fractures. All patients underwent PHILOS plate fixation performed by experienced orthopaedic surgeons. Functional outcomes were assessed using the Constant-Murley score at 6 months postoperatively, with outcomes categorized as Excellent, Good, Fair, or Poor. Complications, including avascular necrosis, implant-related issues, subacromial impingement, malunion, and nonunion, were recorded. Results: Mean age was 42.98 ± 14.40 years. Functional outcomes were classified as Excellent in 32% of cases, Good in 44%, Fair in 14%, and Poor in 10%. Complications included avascular necrosis in 12%, implant-related complications in 8%, subacromial impingement in 4%, and malunion in 10%. Conclusion: PHILOS plate fixation for proximal humeral fractures provides favourable functional outcomes and minimum complications.

Downloads

Download data is not yet available.

References

Court-Brown CM, Caesar B. Epidemiology of adult fractures: A review. Injury. 2006;37(8):691-7.

Donnally III CJ, DiPompeo CM, Varacallo M. StatPearls [Internet]. StatPearls Publishing; Treasure Island (FL): Aug 4, 2023

Aiyer A, Varacallo M, Boateng H, Reid JS. Humeral Shaft Fracture with Ipsilateral Anterior Shoulder Dislocation and Posterior Elbow Dislocation: A Case Report and Review of the Literature. JBJS Case Connect. 2014;4(3):e77.

Iglesias-Rodríguez S, Domínguez-Prado DM, García-Reza A, Fernández-Fernández D, Pérez-Alfonso E, García-Piñeiro J, Castro-Menéndez M. Epidemiology of proximal humerus fractures. Journal of orthopaedic surgery and research. 2021;16(1):402.

McLean AS, Price N, Graves S, Hatton A, Taylor FJ. Nationwide trends in management of proximal humeral fractures: an analysis of 77,966 cases from 2008 to 2017. Journal of Shoulder and Elbow Surgery. 2019;28(11):2072-8.

Boadi PJ, Da Silva A, Mizels J, Joyce CD, Anakwenze OA, Klifto CS, Chalmers PN. Intramedullary versus locking plate fixation for proximal humerus fractures: indications and technical considerations. JSES Reviews, Reports, and Techniques. 2024.

Blonna D, Assom M, Bellato E, Pisanu G, Greco V, Marmotti A, Rossi R. Outcomes of 188 proximal humeral fractures treated with a dedicated external fixator with follow-up ranging from 2 to 12 years. JBJS. 2019;101(18):1654-61.

Alany AM, Mercalose HM, Al-Bayati TA. Outcomes of Percutaneous Pinning Technique in the Management of Two-Part and Three-Part Proximal Humerus Fracture in Adults. Diyala Journal of Medicine. 2020 Dec 15;19(2):129-39.

Sohn HS, Shin SJ. Modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures. Injury. 2019;50(7):1300-5.

Chudik SC, Weinhold P, Dahners LE. Fixed-angle plate fixation in simulated fractures of the proximal humerus: a biomechanical study of a new device. J Shoulder Elbow Surg 2003;12:578-588.

Oldrini LM, Feltri P, Albanese J, Marbach F, Filardo G, Candrian C. PHILOS synthesis for proximal humerus fractures has high complications and reintervention rates: a systematic review and meta-analysis. Life. 2022;12(2):311.

Foruria AM, Martinez-Catalan N, Valencia M, Morcillo D, Calvo E. Proximal humeral fracture locking plate fixation with anatomic reduction, and a short-and-cemented-screws configuration, dramatically reduces the implant related failure rate in elderly patients. JSES international. 2021;5(6):992-1000.

Sapienza M, Pavone V, Muscarà L, et al. Proximal humeral multiple fragment fractures in patients over 55: Comparison between conservative treatment and plate fixation. Heliyon. 2024;10(4).

Geiger EV, Maier M, Kelm A, et al. Functional outcome and complications following PHILOS plate fixation in proximal humeral fractures. Acta Orthop Traumatol Turc. 2010;44:1-6.

Laux CJ, Grubhofer F, Werner CM, et al. Current concepts in locking plate fixation of proximal humerus fractures. J Orthop Surg Res. 2017;12:137.

Norouzi M, Naderi MN, Komasi MH, Sharifzadeh SR, Shahrezaei M, Eajazi A. Clinical results of using the proximal humeral internal locking system plate for internal fixation of displaced proximal humeral fractures. Am J Orthop (Belle Mead NJ). 2012 May 1;41(5):E64-8.

Jacob TT, Nayak M. Functional outcome of patients treated with proximal humeral internal locking osteosynthesis plate in proximal humeral fractures. Int J Res Orthop. 2020;6:1182-5.

Mariadoss A, Thacker J, Gopikrishnan K, et al. Outcome of proximal humeral locking plates in young patients with high-velocity trauma. Arch Bone Jt Surg. 2019;7:38-45.

Downloads

Published

2024-11-20

How to Cite

HAQ , S., SAEED , M., QASIM , M., & HUSSAIN , M. (2024). FUNCTIONAL OUTCOMES OF PROXIMAL HUMERUS FRACTURE USING PHILOS. Biological and Clinical Sciences Research Journal, 2024(1), 1285. https://doi.org/10.54112/bcsrj.v2024i1.1285